FT-100 Series Tap density tester
1. 概述:Overview
具有设定振次和时间两种测量方式,设计符合人体工学,操作简单.符合USP(美国药典)、BP (英国药典)和EP(欧洲药典)的规范要求及GB/T5162-2006/ISO3953:1993(金属粉末 振实密度的测定),仪器含盖国标GB/T 5162-2006/ISO3953:1993中的各项指标。
With set vibration times and time two measurement methods, The design accord with human body engineering, the operation is simple. Meet specification requirements of USP (the United States pharmacopoeia), BP (British pharmacopoeia) and EP (European pharmacopoeia) and GB/T 5162-5162 / ISO3953:1993 (metal powder the determination of tap density), This instrument covers all the indexes in national standard GB/T 5162-2006 / ISO3953:1993
二、适用范围:Scope of application
适用于非金属粉、金属粉体、制药、化工、电池、磨料以及科研教学等领域,是粉体行业振实密度测试的理想仪器。
It is suitable for non-metallic powder, metal powder, pharmaceutical, chemical, battery, abrasive and research teaching etc field , which is an ideal instrument for the tap density testing of powder industry
三、 工作原理: Working principle
将粉末量筒固定在机械振动装置上,振动电机带动机械振动装置上下振动,装有粉末的刻度量筒随机械振动装置而发生有节拍的振动,随着振动次数的增加,量筒里的粉末逐渐振实,振动次数达到设定的次数后,机械振动装置停止振动,读出刻度试管的体积,根据密度的定义:质量除以体积、从而求出振实后的粉末密度。
Powder cylinder fixed in the mechanical vibration device, mechanical vibration device vibrate under driven by vibrating motor, the calibration test tubes which containing powder vibrate with the mechanical vibration device, with the increase of vibration frequency, the powder in the measuring cylinder gradually compact by vibration, When vibration frequency reaching setting the number of times, mechanical vibration device will stop the vibration, Read the volume of the calibration test tube, according to the definition of density: mass divided by volume, thus find out the powder density after compaction.
2. 各型号及参数描述model and parameter description
功能项目/型号 project/model |
FZS4-4 |
FT-100B |
FT-100A |
FT-100CA |
|
3. 测试工位数 Test station number |
1个 one |
2个 two |
|||
4. 测试数据处理方式 Test data processing method |
人工计算 manual computation |
带打印+自动计算 With print + automatic calculation |
|||
5. 量筒配置规格 Measuring cylinder specifications |
25ml、100ml |
25ml、50ml、100ml、250ml |
|||
6. 密度density |
0-9.9999g/cm3 |
||||
7. 测量模式measurement |
振次和时间两种测量方式 Vibration and time measurements |
||||
8. 振幅 range of vibration |
最大14mm,整数1-14mm可调; Maximum 14mm, integer 1-14mm adjustable; |
||||
9. 振动频率 vibrational frequency |
0~300 次/分(连续可调)times/ minute. (continuous adjustable)
|
||||
10.振动时间 time of vibration |
0-9999S |
||||
11.符合标准 meet the standards
|
USP(美国药典)、BP (英国药典)和EP(欧洲药典)的规范;GB/T 5162-2006/ISO3953:1993(金属粉末 振实密度的测定) USP (us pharmacopoeia), BP (British pharmacopoeia) and EP (European pharmacopoeia);GB/T 5162-2006 / ISO3953:1993 (metal powder measuring the tap density ) |
||||
12.量筒要求 Measuring cylinder requirements |
容积Volume 100±1.0ml,刻度部分高H 175±10mm 最小刻度间的容积为1ml, volume of the minimum scale is 1ml 容积为Volume 25±0.5ml刻度部分高H 135±7mm。 最小刻度间容积为0.2cm,测量精度为±0.1cm The volume of the minimum scale is 0.2 cm and the measurement accuracy ±0.1cm |
||||
11.重复性repeatability |
误差Deviation:≤1% |
||||
· 12.准确性Accuracy |
误差Deviation:≤1% |
||||
13.适用范围 · Scope of application
|
非金属粉、金属粉 、制药、化工、电池、磨料以及科研教学等粉体颗粒物料 Non-metallic powder, metal powder, pharmaceutical, chemical, battery, abrasive and scientific research teaching and other powder particle materials |
||||
14.电源Power supply |
交流Ac 220V(50Hz/60Hz)、40W |
||||
15.使用环境 · Operational environment
|
湿度小于85%,无凝结现象,无烟尘,无机械振动源或电磁干扰源 Humidity is less than 85%, no condensation, no smoke, no mechanical vibration source or electromagnetic interference source |
||||
16.选购项目 Buy items |
a.2Q验证文件 b.隔音箱 c.水分仪 d.粉体真密度仪 e.松装密度仪 a.2Q verification file b. sound box c. moisture meter d. powder true density meter e. bulk density meter |
FT-100系列振实密度测试仪
网址:http://fannawang.com/qitafenxiyiqi/40834.html